one.two.two Warning Labels Warning Labels This means Remember to very carefully read through this handbook just before use device. The next labels are a. Usually do not area the product with a sloped surface area. Otherwise the readily available in the event the method unit may perhaps slide, causing private injuries or perhaps the product functions Along with the cellular malfunction.

Utmost 4 instances tasking for a person transmitted beam, leading to fantastic time resolution and better frame charge.

Be aware: To the keep track of, the brightness adjustment will come in advance of contrast. Just after readjusting the keep an eye on’s distinction and brightness, alter all preset and peripheral settings.

Will not use any cables besides the cables provided Using the device by Mindray. three. Utilize the cable presented with This technique to connect the printer. Other cables may well lead to electric shock. Webpage 15: Mechanical Basic safety

Reduce off cable ties connecting the principle device on the Display screen by diagonal cutting pliers, and after that pull out the corresponding cable plugs.

Mindray’s new era of black & white ultrasound method, DP-fifty Skilled, is equipped with Highly developed imaging technologies enabling further penetration and speedier impression acquisition with greater resolution.

The chapter supplies the method to confirm principal operate and general performance of product. This is often only used for reference, not preventive execution. Purpose examining and tests of the portion shall be completed by Mindray company engineers and also the user with each other. Webpage 66: Basic Examination

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi depth mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

iZoom™ allows precise viewing of graphic from distance iWorks™ Protocol can help standardize workflow and decrease exam periods

5.two.3 Geometric positioning precision Longitudinal geometric positioning accuracy  Check Stage: Do changes as the best way in testing the most depth. Record the distance by 20mm Each and every section around the longitudinal targets line using the measurement caliper; Choose the worth with the best mistake (to 20mm), estimate the precision using the components under The measurement caliper needs to be positioned at the higher edge of the concentrate on, Take note:... Web site seventy nine Transverse geometric positioning precision  Take a look at Action: Address the scan area from the phantom with h2o or few gel, gently Speak to the probe While using the scan area Change the depth, building the transverse targets being shown inside the image. Adjust the main focus place to generally be posited beside the transverse targets (the regular is just not obvious) Alter parameters like acquire, TGC, creating Every single transverse targets to get clearly shown. Web page eighty 5.five.two.4 Blackout Space Examination Stage: Address the scan surface area of the phantom with drinking water or pair gel, gently Call the probe Along with the scan surface area Change the depth at a decrease benefit, and set the main focus at the closest place to the scan surface area. Minimize the value of parameters like AP, Achieve till the qualifications sounds just may be viewed. Web page 81: Program Improve And Servicing

Kebutuhan Anda akan alat Dp50rb login profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.

.. Site 161 The indicator on the printer Mistakes arise in the event the adapter turns orange, and the printing printer adapter runs. Disconnect and connect the fails. electrical power adapter, electric power over the printer adapter all over again, and validate whether or not the printing is typical right after one minute. Web site 163: Electrical Basic safety Inspection

Overall performance Take a look at 5.five.one Exam Procedure Resolution Detection depth Geometric Placement Precision Blackout place exam Report the Test pictures five.5.two Check Information The picture utilised here is just for reference, follow the impression influence in the real Take note: scenario. Necessities: Show: set the contrast and brightness on the clinical application benefit (or even the default position) Procedure environment: darkish place, simulating the scientific software ecosystem. Website page seventy six In issue that the transverse resolution testing targets are horizontally shown, record the small length of two targets that may be Evidently recognized. Repeat the Procedure earlier mentioned with the transverse resolution testing targets at other depths. As revealed in figure beneath. Axial resolution ... Site 77 When using the convex probe, continue to keep the transverse resolution tests targets to NOTE: be exhibited near the midline. When utilizing a linear probe with steer perform, never turn on the steer function when complete the transverse resolution check. Zoom within the area where by the targets Positioned if vital. The diameter from the goal position at a particular depth is equal on the transverse resolution with the depth. Web page seventy eight five.

Right after changing the CPU module, crucial file have to be generated once again based on the new MAC deal with and published into HDD on the machine. Or else, the configuration operate on the product or service are going to be missing. After removing the CPU module, Remove panhead screws with washers (12 M3X6) set on the key device box, you can take off the board. Webpage 118 Figure eight-29 Disassemble the Control Panel Assembly (1) Maintain the higher edge of control panel assembly, and open up up the control panel. Figure 8-30 Disassemble the Control Panel Assembly (two) Following getting rid of one countersunk head self-tapping screw PT3X10 set on the user interface and get out the plug of your keyboard and the leading device connecting cables, you may remove the user interface assembly.

A smart new shape, Increased mobility and handy operation make DP-50 compatible for all medical configurations.